The Daniel®
Gas Turbine Flowmeter is highly accurate, with linearity of +/- one
percent or better over turndown ranges as high 200:1.
Customers also choose this meter because of its repeatability, the
ability of the meter to indicate the same reading each time the same
flow conditions exist.
The piping requirement calls for only 10 diameters of pipe and a flow
conditioner upstream of the meter and five diameters of pipe downstream.
The meter sizes range from four to 12 inches.
The fully electronic design enables Daniel to produce this instrument
with fewer moving parts, reducing maintenance and downtime in both the
standard and high-capacity models.
Technological requirements continue to move toward automation, requiring
less operations and maintenance. To meet these evolving requirements,
the Daniel Gas Turbine Meter can provide remote or local readouts. The
meter can be combined with flow computers or pressure and temperature
correctors to provide electronic flow rate and totalized readings.