The Micro Motion RFT9739 transmitter can be used with any Micro Motion sensor to provide precision fluid measurement in a wide variety
of applications. The RFT9739 provides highly accurate mass flow, volume flow, density, and temperature measurements and is approved for legal trade
in custody transfer applications. In addition, the RFT9739 density output can be configured for API gravity and API standard volume for Generalized
Petroleum Products. Available in field-mount and rack-mount versions, the field-mount version is housed in a NEMA 4X (IP65) explosion-proof enclosure
that allows the transmitter to be installed in the same hazardous area as the sensor.
Brief Specifications
Flow accuracy
with ELITE sensors:
+/- 0.10% of flow rate
with F-Series sensors:
+/-0.20% of flow rate
with D, DT, DL sensors:
+/-0.15% of flow rate
Density accuracy
with ELITE sensors
+/- 0.0005 g/cc
with F-Series sensors
+/-.0.002 g/cc
with D, DT, DL sensors
varies by sensor model
Outputs
2 analog (milliampere) outputs
1 frequency/pulse output
1 dual-channel frequency output*
1 optocoupler output*
1 control output
Local display**
Digital Communication
Bell-202 and/or RS-485 serial standards
HART and/or Modbus protocols
Power Supply Options
85-250 VAC
110/115 VAC*
220/230 VAC*
12-30 VDC
*Rack-mount version only.
**Optional on field-mount version. Standard on rack-mount version.