Emerson Process Management Website Home Emerson Corporate BusinessEmerson Corporate WebsiteEmerson OverviewEmerson BusinessesEmerson Investor Relations
Search the Analytical WebsiteEmerson Process Management PlantWebEmerson Process Management Industry CapabilitiesEmerson Process Management News & EventsEmerson Process Management ContactsEmerson Process Management Global Presence
























CAT 100 Continuous Gas Analyzer Transmitter


File Size = 3570 KB
  • Single or dual channel multi-component analyzer
  • CSA-C/US and ATEX-approved for Class I, Zone 1 Group IIB + H2 environments
  • IP 55/IP 66 enclosure (designed to meet NEMA 4X for outdoor installation)
  • Supports NDIR, paramagnetic O2, electrochemical O2 and thermal conductivity detectors
  • Eliminates high-cost, environmentally-controlled shelters
  • Simple, fast and easy maintenance: internal analyzer can be removed and replaced within minutes
  • Optional sample conditioning plate or internal sampling handling options provide a complete, stand-alone analyzer system
  • High-performance, micro-flow NDIR detector, robust solid-state detectors, solvent and corrosion-resistant paramagnetic oxygen and TC cells are available
  • Part of the PlantWeb® field-based architecture and is compatible with DeltaV
  • Analog, digital and relay outputs, serial interface and analog and digital inputs enable sophisticated I/O functionality

PRODUCT DESCRIPTION
Emerson Process Management, the world leader in process gas analyzers, offers the multi-component, multi-technology CAT 100 Continuous Gas Analyzer Transmitter with flameproof (explosion proof) packaging. The CAT 100 provides superior performance and has been designed for precise, continuous gas measurements in a variety of applications.

FIELD-MOUNTABLE HOUSING
The CAT 100 is housed in a Class I, Zone 1 (IIB) + H2 approved transmitter-style enclosure that can be field mounted in the harshest environmental conditions. The enclosure can be mounted near the process without requiring ambient controls or costly and space-consuming shelters. This feature greatly reduces installation and utility costs while vastly improving process efficiency.

MULTI-MEASUREMENT CAPABILITY
The CAT 100 can continuously measure 1 or 2 components in a single analyzer using a combination of non-dispersive infrared (NDIR) spectroscopy, paramagnetic or electrochemical oxygen and thermal conductivity sensors. This exceptional flexibility has been achieved by combining the most sophisticated gas detection sensor technology with microprocessor controlled signal processing.

MEASUREMENTS
The CAT 100 brings together more than 40 years of development and process application expertise blending the latest sensors, digital signal processing and software technologies. The CAT 100 can satisfy the most demanding single or dual analysis requirements. Many gas components can be measured including: Carbon Monoxide (CO), Oxygen (O2), Carbon Dioxide (CO2), Water (H2O), Propane (C3H8), Methane (CH4), Butane (C4H10), Hydrogen (H2), Hexane (C8H14) and Ethylene (C2H4).

TOUCHPAD CONTROL
The CAT analyzer's magnetically operated user interface is placed behind an impact-tested safety glass. It offers the user setup and control capabilities without needing to open the analyzer housing or shut off power. All analyzer key functions are accessible including autocalibration, limit alarms, range selection (O2 and IR with scope function), diagnostics and much more by simply pointing a magnetic tool at the appropriate function key.

SAMPLE HANDLING/CONDITIONING OPTION
With the addition of a sample handling and conditioning system mounted to an integral plate, the CAT 100 becomes a complete stand-alone in-field, transmitter-style analyzer system. The sample conditioning plate option is a small and efficiently designed system that is bolted directly onto the analyzer housing at the factory for a final one-piece system construction. This one-piece unit can then easily be mounted to a the process pipe. This feature offers highly efficient process monitoring and fast installation at low cost. The sample conditioning system is designed by experienced Emerson Process Management engineers who will tailor the sample handling system around your particular process parameters and required measurements.

Alternately, the CAT 100 design can incorporate internal sample handling options such as a gas sampling pump, flowmeter, flow restrictor and solenoid valve block for autocalibration and remote valve and calibration control. Two pumps, flowmeters and valve blocks are available as a special solution for parallel tubed benches.

FOUNDATION™ FIELDBUS COMMUNICATIONS OPTIONS
FOUNDATION™ fieldbus offers the latest, most innovative field control architecture available. A two-wire digital communications protocol enables individual instruments to communicate together and be interoperable with other FOUNDATION™ fieldbus capable instruments. This communications protocol can carry vast amounts of information that is not accessible by using standard analog or digital data acquisition methods – information not only about the process, but also about the equipment controlling it.