Emerson Process Management Website Home Emerson Corporate BusinessEmerson Corporate WebsiteEmerson OverviewEmerson BusinessesEmerson Investor Relations
Search the Analytical WebsiteEmerson Process Management PlantWebEmerson Process Management Industry CapabilitiesEmerson Process Management News & EventsEmerson Process Management ContactsEmerson Process Management Global Presence
























Model Bx438 Dissolved Oxygen Sensor


File Size = 88 KB
File Size = 213 KB
  • DESIGNED FOR CARBONATED BEVERAGES
  • LONGER SENSOR LIFE
  • LESS MAINTENANCE REQUIRED
  • FAST RESPONSE
  • MINIMAL FLOW SENSITIVITY
  • LOWER TOTAL COST OF OWNERSHIP
  • MINIMAL CO2 OFFSETS
FEATURES AND APPLICATIONS
The Model Bx438 sensor is designed to monitor trace levels of dissolved oxygen in beer and other carbonated beverages. The Bx438 sensor utilizes a robust membrane, which increases the life of the membrane. The sensor is designed to withstand significantly more clean in place (CIP) cycles than other dissolved oxygen sensors.

Unique Design: Most dissolved oxygen sensors operate by reduction of oxygen at the surface of the cathode. If the cathode is in direct contact with the solution, then interference effects from other substances may lead to inaccurate readings. The Model Bx438 cathode is covered with a gas permeable membrane. The oxygen diffusing through the membrane is completely reduced at the cathode, and the current between anode and cathode is proportional to the oxygen content in the sample.

The design for the membrane is the key to achieving high performance. The Model Bx438 uses a proprietary membrane material. This thick, steel-meshedreinforced, double layer membrane enables the sensor to withstand high pressures and temperatures while maintaining high diffusion rates, resulting in stable outputs and fast response times.

Longer Sensor Life/Less Maintenance: Due to the unique design of the sensor, maintenance is rarely required. The special double membrane design is less sensitive to contamination from protein and other fouling agents. The electrode construction guarantees excellent stability even after numerous sterilization cycles. Competitive dissolved oxygen sensors require maintenance after as few as 3-5 cycles. The model Bx438 sensor lasts through as many as 30-50 cycles.

Minimal Flow Sensitivity: Model Bx438 membrane material and overall design ensure that the flow rate has minimal effect on the sensor's measurements. The unique design also experiences minimal drift in low flow environments.

Zero Polarization Voltage: Many competitive amperometric dissolved oxygen sensors set the polarization voltage to -670 mV. This set point may lead to offset readings due to carbon dioxide effects at low oxygen concentrations. The Model Bx438 sensor uses a zero polarization voltage setpoint, which results in the most accurate dissolved oxygen readings.
Home · Gas Division · GC Division · Liquid Division · On-line Store · Order Status
Contact Us · Library · Links · Support · Training · Careers
 
Comments to the WebMaster 8.2.2005 EMERSON. CONSIDER IT SOLVED ®2009 Emerson Electric Co.  