Key
Specifications |
| Measurement Principle |
Ultrasonic, time-of-flight |
| Measuring Range |
26 ft (8 m) for Rosemount 3101
36 ft (11 m) for Rosemount 3102 and 3105 |
| Instrument Accuracy |
Model 3101: ± 0.2 in. (5 mm) for <3.3 ft (1 m),
± 0.5% of measured distance for >3.3 ft (1 m)
Models 3102 and 3105: ± 0.1 in. (2.5 mm) <3.3 ft (1 m),
±0.25% of measured distance for >3.3 ft (1 m)
|
| Level Resolution |
Better than 1/16" (1 mm) |
| Blanking Distance |
12" (0.3m) |
| Output |
4-20mA for 3101
4-20mA with superimposed digital HART® communication for 3102 and 3105 |
| Temperature/Pressure Rating |
Refer to the Product Data Sheet (PDF @ 400KB) |
| Hazardous Location Approvals (for 3105 only) |
Intrinsic Safety (ATEX, CSA, IECEx, FM) |
| Display |
Standard 4/5 digit display for configuration purposes. |
| Output Variables |
Level, Distance for 3101
Level, Distance, Volume, Open Channel Flow for 3102 and 3105 |
| Enclosure |
Polyurethane-covered die-cast Aluminum housing. |
| Ingress Protection |
NEMA 4X, IP66 |
| Configuration Tools |
AMS, 275/375 Field Communicator, Rosemount 3490
Series Universal Controller or any other DD- or EDDL-compatible host. |