Key
Specifications |
| Measurement Principle |
Guided Wave Radar using TDR (Time Domain Reflectometry) Technology |
| Maximum Measuring Range |
77 ft (23,5 m) from upper reference point |
| Instrument Accuracy |
± 0.2 inch (5 mm) for probes ≤ 16.4 ft (5 m) ± 0.1% of measured distance for probes > 16.4 ft (5 m) |
|
Power Supply |
Loop-powered (2-wire), 11-42 VDC (11-30 VDC in IS applications, 16-42 VDC in XP applications) |
| Output |
4-20mA with superimposed digital HART® communication |
| Temperature/Pressure Rating |
Refer to the Product Data Sheet (PDF@1.4Mb) |
| Hazardous Location Approvals |
ATEX: Flameproof and Intrinsic Safety
CSA: Explosionproof and Intrinsic Safety
FM: Explosionproof and Intrinsic Safety
IECEx: Eplosionproof and Instrinsic Safety
|
| Display |
Integral digital display (Option) |
| Output Variables |
Level, Distance, Interface Level, Interface Distance, Volume,
Internal Temperature (Housing), Aout current and % of Range
|
| Enclosure |
Polyurethane-covered die-cast Aluminum housing with dual compartments.
|
| Ingress Protection |
NEMA 4X, IP66
|