Emerson Process Management Website Home Emerson Corporate BusinessEmerson Corporate website Company OverviewEmerson Corporate BrandsEmerson Corporate Investor Relations  
Search Emerson Process Management WebsiteEmerson Process Management PlantWebEmerson Process Management Industry CentersEmerson Process Management News & EventsEmerson Process Management ContactsEmerson Process Management Global Presence



 
 

Rosemount 3051 Smart Pressure Transmitter with FOUNDATIONTM Fieldbusffcheck.gif (1889 bytes)

The Rosemount 3051 is one of the World's first pressure transmitter to pass the Fieldbus Foundation's interoperability test!

Model 3051CThe Rosemount 3051 Pressure transmitter with FOUNDATION fieldbus is the newest extension to the Rosemount pressure product line. Loaded with the same superior features found in the HART-based 3051, the new fieldbus platform offers even more functionality and user benefits. The 3051 with FOUNDATION fieldbus is the ultimate transmitter for both critical and non-critical pressure applications.

  • Total Performance of 0.15% represents transmitter performance under real operating conditions and increases loop performance and productivity.
  • Performance over time represents transmitters performance over a period of time under changing conditions
    -Guaranteed stability of 0.125% over a five year period.
    -Reduced calibration frequencies save operations and maintenance costs.
  • Dynamic Performance measures the speed of the transmitter's response to process changes.
    -7 to 10 faster than other fieldbus transmitters
    -Increased control and optimization of the critical loop.
    -Increased plant safety and productivity.
  • Rosemount Complete Point Solutions™ are engineered measurement solutions that combine the best products and installation practices.

Emerson Process Management PlantWeb™ Architecture
PlantWeb is the architecture that uses the power of intelligent field devices to improve plant performance. The Emerson Process Management DeltaV system with AMSinside optimizes the field device intelligence during startup, operation, and maintenance. FOUNDATION fieldbus allows the implementation of PID control in the field device. Moving control closer to the process improves loop performance, reduces plant variability, and greatly reduces the necessary size of the control rooms.

General Specifications

Total Performance + 0.15% of span
Reference Accuracy + 0.065% of span
Output FOUNDATION fieldbus 31.23kb H1
Weight 6 lb (2.72 kg)
Dimensions 6.4 x 3.2 x 7.8 (163 x 81 x198 mm)

More Information

Reduce calibration costs by $600 per transmitter!
Over a 5-year period, a typical competitor's transmitter needs seven calibrations to deliver the required performance, while the 3051 needs only one. 5 Year stability saves maintenance costs and reduces plant downtime!
Want a more accurate pressure measurement?
The Rosemount 3051 is the best performing transmitter for critical custody transfer applications.

Technical Documentation

Device Description / Capabilities Files


Emerson Process Management, Rosemount Division, 8200 Market Blvd. Chanhassen, MN USA 55317
North America: 1-800-999-9307    International: 952-906-8888  Fax:  952-949-7001

 

Contact Emerson Process Management,
Rosemount Division


Last Updated 07/10/07


© Emerson, 1996-2007
Legal and Privacy Statements