Models 3144 & 3244MV Smart  Temperature Transmitters 

Model 3144 The Models 3144 and 3244MV temperature transmitters provide superior accuracy, stability, and reliability, making them the industry-leading temperature transmitters used in control and safety applications. The Model 3144 is a single-sensor input transmitter. The Model 3244MV has a dual-sensor input capability that allows the transmitter to accept simultaneous input from two independent sensors. You can use this transmitter for measuring differential temperatures, averaging temperature or redundant temperature measurement.

  • Industry leading 5 year stability, which reduces maintenance costs
  • Hot Backup® feature in the Model 3244MV automatically switches to the backup sensor if the primary sensor fails
  • Transmitter-Sensor matching eliminates sensor interchangeability error, which improves accuracy by 75%
  • Dual-compartment housing that provides the highest reliability in harsh environments
  • Highest accuracy differential temperature measurement on the Model 3244MV
  • Sensor Drift Alert in the Model 3244MV enables continuous monitoring of the differential temperature for two sensors.
  • Integral LCD meter with large, easy to read display
  • RTD, thermocouple, ohm and millivolt inputs accepted
  • Hard-wired failure jumper for reliable failure modes
 

Key Specifications

Digital Accuracy  + 0.10° C (+ 0.18° F) for Pt100 RTD 
D/A Accuracy  + 0.02% of span 
Ambient Temperature Effects  0.0015°C per 1.0°C change in ambient for Pt100 RTD 
Stability  + 0.1% of reading or 0.1° C, whichever is greater for two years for RTDs 
+ 0.25% of reading or 0.25° C, whichever is greater for five years for RTDs 
Input  2-, 3-, and 4-wire RTD, thermocouple, millivolt, or ohm 
Output  4-20 mA dc with HART protocol 
Supply Voltage  12.0 to 42.4 V dc (with 250 ohm load, 17.75 V dc is required) 

More Information

Interested in more reliable temperature measurement?
The 3244MV has your answer with  Hot Backup® automatic sensor switch-over in case of sensor failure
Want a more accurate temperature measurement?
Eliminate sensor interchangeability error using Transmitter-Sensor matching available with the Models 3144, 3244MV, or 644. 
Looking for a Temperature Complete Point Solution?
Rosemount offers a wide variety of sensors, thermowells, connection heads and more

 

Technical Documentation

AMS 1.4.1 Device Template Install Kits 


Emerson Process Management, Rosemount Division, 8200 Market Blvd. Chanhassen, MN USA 55317
North America: 1-800-999-9307    International: 952-906-8888  Fax:  952-949-7001

 
 

Contact Emerson Process Management,
Rosemount Division


Last Updated 11/19/08 


© Emerson, 1996-2008
Legal and  Privacy Statements