Rosemount 3144P Temperature Transmitter with FOUNDATION™
fieldbus
Rosemount
Engineers continue to set the standard for temperature measurement with the
Rosemount 3144P with FOUNDATION™
fieldbus Temperature Transmitter. It is truly the ultimate transmitter for
control and safety temperature measurement applications. The multivariable dual-sensor input
capability of the Rosemount 3144P allows it to accept
simultaneous inputs from two sensors. You can use the
Rosemount 3144P for differential, averaging or redundant
temperature measurement. The transmitter also offers improved
noise rejection. Transmitter Sensor Matching maximizes
accuracy.
Rosemount 3144P FOUNDATION
fieldbus Capablities
| |
|
 |
| |
-
Regulatory Control Suite (2 PIDs with auto-tune for easy loop
tuning, 1 Signal Characterizer, 1 Arithmetic,
and 1 Output Splitter) offers value and flexibility when generating control
strategies.
|
|
|
|
|
|
|
| |
|
| |
|
| |
|
|
|
|
| |
|
| |
|
| |
|
| |
|
|
|
|
| |
|
Emerson Process Management PlantWeb® Architecture
PlantWeb is the architecture that uses the power of intelligent field
devices to improve plant performance and immediate troubleshooting
assistance. The Emerson Process Management DeltaV system with AMSinside optimizes the
field device intelligence during startup, operation, and maintenance.
FOUNDATION fieldbus allows the implementation of PID control in the field
device. Moving control closer to the process improves loop performance,
reduces plant variability, and greatly reduces the size of the
control room.
Rosemount 3144P Powers PlantWeb
The Rosemount 3144P Temperature Transmitter is an important element of the
PlantWeb digital architecture. This advanced instrument Powers
PlantWeb by eliminating sensor error, communicating important temperature
diagnostics and PlantWeb alerts to ensure process health.
Key Specifications |
| Accuracy |
+ 0.10° C (+0.18° F) for Pt100
RTD |
| Ambient Temperature Effects |
0.0015°C per 1.0°C change in
ambient temperature for Pt100 RTD |
| Stability |
+ 0.1% of reading or 0.1° C, whichever
is greater, for 2 years for RTDs + 0.25% of
reading or 0.25° C, whichever is greater, for 5 years for RTDs |
| Inputs |
2-, 3-, and 4-wire RTDs, thermocouple,
millivolt, ohm |
| Output |
FOUNDATION fieldbus |
| Function Blocks |
Standard: 3 Analog Inputs and 1 Input
Selector Optional: 2 PIDs, 1 Signal Characterizer, 1
Arithmetic, and 1 Output Splitter, Advanced Diagnostics |
| Supply |
9.0 to 32 V dc, 11 mA maximum |
| Weight |
Aluminum: 3.2 lb (1.4 kg): SST: 7.9 lb (3.6
kg) |
| Dimensions |
4.4 x 4.4 x 4.4 in (112 x 112 x 112
mm) |
More Information
Technical Documentation
|
Device Description / Capabilities Files
|
|
|
|
|
Emerson Process Management,
Rosemount Division, 8200 Market Blvd.
Chanhassen, MN USA 55317
North America: 1-800-999-9307 International:
952-906-8888 Fax: 952-949-7001
|
|