BUS Communication for Pneumatic actuators

 

El-O-Matic bus-communication products provide the possibility to control pneumatic actuators via various bus systems. Fieldbus interface cards are provided as options in our LDN, HDN and FF34 products. They can be supplied in water and dust proof versions as well as in explosion proof versions.

The LDN switchbox is available with ASI (actuator sensor interface), the HD box with ASI, Profibus-DP or PA and the FF34 with Fieldbus FoundationTM. All have basic functionality of two-way communication, the fieldbus controller receiving input from the two position indicating switches (mechanically adjustable 0-90º), and an output to the solenoid valve(s) which may be to mono-stable or bi-stable. Bus wiring may be 2 wire or 4 wire depending on the system.
 

AS Interface In LDN Box


AS interface in LDN box
 

ASI application, weatherproof.
  • Weatherproof housing IP65.
  • LED indication of position, output and supply voltage
  • Output for a single, mono-stable solenoid (24 V DC, 2.6 W max.).
  • Power supply for sensor and valve of AS interface.

 

AS Interface In HD Box




AS interface in LDN box
 

ASI application, weatherproof or explosion proof.
  • Weatherproof housing IP67.
  • Explosion proof housing EEx d IIC T6
  • LED indication of position and supply voltage
  • Output for a single, mono-stable solenoid (24 V DC, 2.6 W max)
  • Power supply for sensor and valve of AS interface.

Profibus-DP In HDN Box


Profibus-DP application, weatherproof or explosion proof.
  • Weatherproof housing IP67.
  • Explosion proof housing EEx d IIC T6
  • LED indication of supply voltage and acceptance by the bus.
  • Output for mono or bi-stable solenoid (24 V DC, 2.6 W max.).
  • Single supply connection for valve and I/O card.
  • Automatic baud rate detection up to 12 Mbit/s.

Profibus-PA In HDN Box



Profibus-DP or PA in HD box

 


Profibus-PA application, 2-wire intrinsically safe.
  • Weatherproof housing IP67.
  • Certification in progress for explosion proof EEx ia and Profibus-PA
  • LED indication of supply voltage and acceptance by the bus.
  • Output for mono- or bi-stable solenoid (7 V DC, 14 milli Watt max.).
  • Additional 4-20 mA analog input for external sensors.

Fieldbus FoundationTM In FF34 Box



Fieldbus FoundationTM in FF34 housing

Digital control with extra analogous input
  • Weatherproof housing IP65.
  • LED indication of position and power supply.
  • Output for mono- or bi-stable solenoid (24 V DC, 2.6 W max.)
  • Single supply connection for valve and I/O card.
  • Extra 4-20 mA analog input for external sensors.